Subverting Traditional Enterprise-level Power Analyzer

Unique Enterprise R&D Testing

Learn more about parameters>

PA3000 Power Analyzer Parameters

Input parameters:

Input parametersParameter description
Measurement rangeVoltage300mV、1V、3V、10V、30V、100V、300V、600V、1000V
CurrentDirect input (Crest factor is 3) 
5A:10mA、20mA、50mA、100mA、200mA、500mA、1A、2A、5A
30A: 300mA、1A、3A、10A、15A、30A
50A: 1A、3A、10A、15A、30A、50A
Sensor input (Crest factor is 3)30mV、100mV、300mV、1V、3V、10V
Maximum continuous allowable input valueVoltagChoose the lower value of 2000V peak value and 1300V voltage RMS
CurrentDirect input 
5A:Choose the lower value of 15A peak value and 6.5A RMS
30A: Choose the lower value of 60A peak value and 33A RMS
50A: Choose the lower value of 90A peak value and 55A RMS
Sensor inputPeak value less than or equal to 4 times of the range; RMS value less than or equal to 2 times of the range
Maximum transient allowable input value
(≤ 1s)
VoltageChoose the lower value of 3000V peak value and 1500V RMS
CurrentDirect input 
5A:Choose the lower value of 22.5A peak value and 10A RMS
30A:Choose the lower value of 80A peak value and 40A RMS
50A:Choose the lower value of 100A peak value and 60A RMS
Sensor inputPeak value less than or equal to 5 times of the range; RMS value less than or equal to 3 times of the range
Input impedancePA3000
Voltage input impedanceInput resistance:2MΩ,input capacitance:10pF
Current input impedance5A: Input resistance:100mΩ,Input inductor:0.07μH
30A: Input resistance:10mΩ,Input inductor:0.03μH
50A: Input resistance:5mΩ,Input inductor:0.07μH
Sensor voltage input impedanceInput resistance:1MΩ,input capacitance:45pF
Input parameterPA3000
nput bandwidthDC,0.1Hz~1MHz
Sampling rate200KS/s
Maximum continuous common mode voltage1000Vrms

Accuracy:

Frequency range of input signalPA3000
  Voltage / CurrentPower
DCCurrent 5A Board card:0.05+0.10+20uA
Current 30A Board card:0.05+0.05
Current 50A Board card:0.05+0.05
Voltage/Sensor:0.05+0.05
Current 5A Board card:
0.05+0.10+20uA* Voltage reading
Current 30A Board card:0.05+0.10
Current 50A Board card:0.05+0.10
Voltage/Sensor:0.05+0.10
0.1Hz ≤ f < 30Hz0.10 + 0.200.20 + 0.30
30Hz ≤ f < 45Hz0.03 + 0.050.05 + 0.05
45Hz ≤ f < 66Hz0.01 + 0.030.02 + 0.04
66Hz ≤ f < 1KHz0.03 + 0.050.05 + 0.05
1KHz ≤ f < 10KHz0.10 + 0.050.15 + 0.10
10KHz ≤ f < 50KHz0.30 + 0.100.30 + 0.20
50KHz ≤ f < 100KHz2.00 + 0.202.00 + 0.30
100KHz ≤ f < 500KHz5.00 + 1.008.00 + 2.00
500KHz ≤ f ≤ 1MHz6.00 + 1.0010.00 + 2.00

The measurement accuracy of the power analyzer is calculated under the following conditions: Temperature: 23±1℃; Humidity: 30-70% RH; Input signal: sine wave; Common mode voltage: 0V; After preheating, line filter: OFF; λ (Power factor): 1; Crest factor: 3. After preheating for 30 minutes, f = frequency. Data update rate: 500 ms.

Display :

Display ParameterPA3000
Display12.1 inches color LCD display
Resolution1280×800pixels
Touch screenSupport for touch screen operation
Display update rateSame as the data update rate

Storage :

Internal SSD capacity60G storage capacity supports long-time storage of more than 10,000 hours (normal)
USB storage interfaceSupport for USB storage interface

Measurement Function/Measurement Condition :

Data update rateSelect from 10ms、50ms、100ms、250ms、500ms、1s、2s、5s、10s、20s
Display update rateSame as the data update rate
Response timeSame as the data update rate

Harmonics measurement (PLL synchronous source method) :

PA3000
Fundamental frequency of PLL sourceSampling rate(S/s)Window width relative to FFT data length
(fundamental frequency)
Maximum harmonic analysis orderNumber of sampling points
10~20Hzf×320031289600
20~40Hzf×160061289600
40~55Hzf×960101289600
55~75Hzf×800121289600
75~150Hzf×480201289600
150Hz~440Hzf×320301289600
440Hz~1.1KHzf×16060809600
1.1KHz~2.6KHzf×80120409600

Motor function –analog quantity input parameters :

Input modeSafety BNC, floating, isolation, electrical isolation among A, B, Z of TORQUE and SPEED
Input impedance1MΩ±100kΩ
Range1V、2V、5V、10V、20V
Cut-off frequency (configurable)100Hz,10kHz,50kHz,OFF
Effective measurement range±110%
Maximum allowable voltage±22V
Maximum common mode voltage±42Vpeak
Number of bits16bit
Sampling rate200kHz
Synchronous sourceU1~U6/I1~I6/EXT
Accuracy±(0.05% reading + 0.05% range)
Temperature drift±0.03% range/℃

Motor function –pulse frequency input parameters :

Input modeSafety BNC, floating, isolation, electrical isolation among A, B, Z of TORQUE and SPEED
Input impedance1MΩ±100kΩ
Frequency range1Hz~1MHz
Input amplitude range±22Vpeak
Maximum common mode voltage±42Vpeak
Effective amplitude1V
Minimum high pulse width2.5µS or more
Accuracy±(0.05% reading + 1mHz)

Waveform sampling data storage function :

Storage itemsVoltage waveform, current waveform, computing waveform, FFT computation data, rotational speed, analog quantity of torque, harmonic data, custom function
Storage modesNormal, real-time, integration synchronization, conditional trigger
Data typeValue, waveform, value+waveform
File typeCSV format, PAD format
Storage Internal DOM, U disk

Integration function :

ModeThe manual, standard, continuous, real-time standard and real-time loop mode can be selected.
WP± modeCharging/discharging, electricity purchase/sale
TimerSet the timer to stop integration operations automatically. 0000h00m00s~10000h00m00s
Stop countingThe integration time and value will be maintained and the integration operation will be stopped when the integration time reaches its maximum value (10000 hours) or the integration value reaches the maximum/minimum display integration value (±999999M).
Accuracy±( power or current accuracy + time accuracy )
Time accuracy ± 0.02% of reading

0.05% power measurement accuracy

PA3000 power analyzer uses the advanced design platform architecture in the embedded field, from the front-end analog circuit design to DSP and FPGA high-speed arithmetic processing circuit design, and finally to the industrial X86 control technology, each of which we have done optimization processing, eventually make PA3000 reached the power measurement accuracy up to 0.05%.

1000V/50A, 7 elements direct measurement

PA3000 Power Analyzer makes use of a 100MHz synchronous clock with high-stability temperature compensation to avoid the measurement error caused by temperature drift, keeping the phase error of each element within 10ns to ensure accurate measurement of active power and power factors.

Harmonics up to 256th order

PA3000 power analyzers have the bandwidth of DC/0.1Hz-1MHz. Thanks to the PLL source frequency-doubling technology, the harmonics measurement with faster speed and wider dynamic range has become realized. In harmonics mode, they can make accurate tests of fundamental voltage, fundamental current, power, phase, harmonic component and total harmonic distortion factor (THD).

Bivector graph analysis

PA3000 power analyzer can measure and display the vector graph of the inverter’s three-phase input and output at the same time, and analyze the phase angle between each input and output phase so as to precisely assess the impact that the angular difference of the input signal has on the output signal.

60G data storage and excellent data format analysis

PA3000 power analyzer is equipped with a solid state disk (SSD) of 60G, which is capable to perform massive data storage. It can even allow users to connect the USB flash drive directly so as to store all the data needed. It supports a variety of formats such as PAD and CSV, and the storage time is controlled at will, thus storage is no longer an issue.